Overview of all products
Here you can see all our order items. Use the extensive filter options to find the suitable product for you.
With the help of the button "Add to watchlist" you can save articles on your watchlist.
Afterwards, you can request your saved watch list as a quotation via a contact form.
Please feel free to contact us
If you have any questions or would like more information, please do not hesitate to contact our sales team.
Contact us
Telephone: +49 (0) 511 37298-0
E-Mail: sales@esd.eu
Categories
- Accessories (102)
- CAN Bus (174)
- CAN Interface (85)
- CPU Board/Module (9)
- EtherCAT (36)
- Gateway/Bridge (21)
- IO-Modules (21)
- Networking (5)
- Slot card system (62)
- Software (83)
Formfactors
- AMC (3)
- CompactPCI (17)
- CompactPCI Serial (7)
- ISA (3)
- M.2 (2)
- PC/104 (1)
- PCI (18)
- PCI-104 (1)
- PCIe (21)
- PCIeMini (5)
- PMC (14)
- Railmount (53)
- USB (9)
- VME (11)
- XMC (10)
Number CAN-Channels
Protocols
- ARINC825 (53)
- CAN FD-Layer 2 (37)
- CAN-Layer 2 (126)
- CANopen (111)
- DeviceNet (4)
- EtherCAT (43)
- Ethernet (11)
- Ethernet/IP (2)
- J1939 (90)
- LIN (5)
- OPC UA (2)
- Profibus (8)
- PROFINET (7)
Supported operating systems
- FreeRTOS (2)
- Linux (93)
- On Time RTOS-32 (27)
- OS-9 (9)
- QNX4 (8)
- QNX6/7 (97)
- RTOS-UH (6)
- RTX (47)
- RTX64 (58)
- SGI-IRIX6.5 (5)
- Solaris (5)
- TenAsys INtime 6/7 (37)
- VxWorks (81)
- Windows 10/11 (2)
- Windows 7/8/10/11 (107)
- Windows CE.NET (7)
Interfaces
- CAN (118)
- CAN FD (29)
- CANopen Device (18)
- CANopen Manager (9)
- DeviceNet (4)
- EtherCAT Slave (9)
- Ethernet (15)
- ISA (4)
- LIN (1)
- PCI (46)
- PCIe (43)
- Profibus (8)
- PROFINET (5)
- Serial Interface (9)
- USB (16)
- VME (7)
Features
- Bus-Mastering (DMA-Support) (50)
- CiA 301 compliant (21)
- CiA 401 profile (15)
- CiA 404 profile (1)
- EKF Product (10)
- esd Advanced CAN Controller (esdACC) (46)
- esd CAN Error Injection (9)
- EtherCAT Master capable (10)
- EtherCAT Slave capable (9)
- Expansion board (9)
- Extended temperature range (7)
- galvanically isolated (132)
- HW-Timestamp capable (51)
- IRIG-B capable (9)
- Low profile slot version (6)
- MSI-IRQ capable (43)
- Part of the CAN SDK (8)
- Runtime license (26)
- SIC transceiver for CAN (1)
- Software Application (9)
- Software Bundle (17)
- Software Stack (25)
- Starter Kit (2)
- Support & Maintenance Contract (13)
I/O Types
CAN-CBM-DP (2.0B)
C.2844.05CANbloc-Mini DIN-rail module Profibus-DP-Slave / CAN-layer 2 Gateway, for CAN 2.0B, 29 Bit support, CAN-physical Layer according to ISO11898, electrically isolated, data transfer rates up to 1 MBit/s, DP-Physical Layer: RS-485, electrically isolated; Manual and GSD file on CD-ROM; additionally the RS-232 can be used for service, development or configuration purposes
CAN-CBM-REL4
C.2833.01CANbloc-Mini-Module for CANopen 4 relay output, 2x changeover, 2x close; also available in extended temperature range -40-+85°C
CAN-CBX-AI420
C.3030.02CANopen module with 4 differential analog inputs via 24-bit Sigma-Delta ADC for voltage range ±10V. Inputs with up to 20-bit effective and 16-bit p-p resolution at sampling rates of up to 2kHz. Galvanic isolation of the analog inputs. CANopen according to CiA 301 and CiA 401 Device Profile for Generic I/O Modules. Connectors for wire end ferrules included in the scope of delivery.
CAN-CBX-AI814
C.3020.02CANopen module with 8 analog single-ended inputs for the ±10V voltage range. Inputs with 14-bit resolution, data rates up to 1kHz and galvanic isolation. CANopen according to CiA 301 and CiA 401 Device Profile for Generic I/O Modules. Connectors for wire end ferrules included in the scope of delivery.
CAN-CBX-AO412
C.3040.02CANopen module with 4 analog ±10V outputs and max. 10 mA output current. Outputs with 12-bit resolution plus sign and galvanically isolated. CANopen according to CiA 301 and CiA 401 Device Profile for Generic I/O Modules. Connectors for wire end ferrules included in the scope of delivery.
CAN-CBX-Bridge-FD
C.3090.02CAN DIN rail module with 2 CAN FD interfaces with up to 8 MBit/s and physical layer according to ISO-11898 with galvanic isolation on COMBICON connectors. Firmware with bridge function for setting baud rate and filters for each CAN interface via serial RS-232 configuration interface.
CAN-CBX-COM2 2xRS232
C.3055.02CANopen module for 2 serial RS232 interfaces. Configuration and protocol according CANopen DS301, CAN Interface according to ISO 11898, galvanic isolation via optocoupler, supports In-Rail-Bus
CAN-CBX-CPU5201 Linux
C.3071.02PowerPC MPC5121 with FPU, 400MHz 0,5 GB DRAM, 1 GB Flash, RTC 1x 10/100BASE-T Ethernet, 1x RS-232 1x USB-Host 2.0, Full-Speed 1x CAN, ISO 11898-2, optical isolated 1x CAN, ISO 11898-2 on In-Rail-Bus; Operating system: Linux
CAN-CBX-CPU5201 QNX
C.3071.04PowerPC MPC5121 with FPU, 400MHz, 0,5 GB DRAM, 1 GB Flash, RTC, 1x 10/100BASE-T Ethernet, 2x RS-232 serial port, 1x USB-Host 2.0, full speed, 1x CAN, ISO 11898-2, optical isolated, 1x CAN, ISO 11898-2 on In-Rail bus; Operating system: QNX 6.4
CAN-CBX-CPU5201/DP QNX
C.3071.06PowerPC MPC5121 with FPU, 400MHz, 0.5 GB DRAM, 1 GB Flash, RTC, 1x 10/100BASE-T Ethernet, 2x RS-232 1x USB host 2.0, full speed 1x CAN, ISO 11898-2, optical isolated, 1x CAN, ISO 11898-2 on in-rail bus for extension with CBX-IO modules 1x Profibus-DP slave, VPC3+ Profibus controller, optical isolated; Operating system: QNX 6.4;
CAN-CBX-DIO8
C.3010.02CANopen module with 8 digital channels with 24V/1A each, each channel can be configured independently as an input or output. CANopen according to CiA 301 and CiA 401 Device Profile for Generic I/O Modules. Connectors for wire end ferrules included in the scope of delivery.
CAN-CBX-Pt100
C.3032.02CANopen module with 4 independent channels with 24-bit Sigma-Delta ADC for high-precision RTD (e.g. Pt100 or Ni100) and resistance measurements. Measurements in two- or four-wire technology with selectable sampling rates of up to 1000 PLC. CANopen according to CiA 301 and CiA 404 Device Profile Measuring Devices. Connectors for wire end ferrules included in the scope of delivery.