Overview of all products
Here you can see all our order items. Use the extensive filter options to find the suitable product for you.
With the help of the button "Add to watchlist" you can save articles on your watchlist.
Afterwards, you can request your saved watch list as a quotation via a contact form.
Please feel free to contact us
If you have any questions or would like more information, please do not hesitate to contact our sales team.
Contact us
Telephone: +49 (0) 511 37298-0
E-Mail: sales@esd.eu
Selected filters
Categories
- Accessories (4)
- CAN Bus (37)
- CAN Interface (3)
- CPU Board/Module (4)
- EtherCAT (7)
- Gateway/Bridge (21)
- IO-Modules (17)
- Networking (5)
- Software (1)
Number CAN-Channels
Protocols
- CAN FD-Layer 2 (2)
- CAN-Layer 2 (37)
- CANopen (26)
- DeviceNet (2)
- EtherCAT (10)
- Ethernet (6)
- Ethernet/IP (2)
- J1939 (4)
- Profibus (8)
- PROFINET (7)
Supported operating systems
Interfaces
- CAN (40)
- CAN FD (2)
- CANopen Device (16)
- CANopen Manager (4)
- DeviceNet (2)
- EtherCAT Slave (3)
- Ethernet (10)
- PCIe (1)
- Profibus (8)
- PROFINET (5)
- Serial Interface (8)
- USB (7)
Features
- CiA 301 compliant (17)
- CiA 401 profile (15)
- CiA 404 profile (1)
- EtherCAT Master capable (4)
- EtherCAT Slave capable (3)
- galvanically isolated (42)
- HW-Timestamp capable (2)
- Software Bundle (1)
- Starter Kit (1)
I/O Types
AMC-ADIO-Adapter
U.1001.10DIN-EN rail mounting module connecting 10-pin har-link socket connector to 14-pin COMBICON style connector FK-MCP 1,5/14-STF-3,81.
AMC-ADIO24-HD50-Adapter
U.1001.09Adapter from SCSI connector 50-pin connector via ribbon cable (0,5m) to transfer/interface modules (50-pin, screw connection, mounting on standard DIN rail)
CAN-CBM-AI4
C.2831.02CANopen module, 4 analog inputs, 0...10V / 0...20mA, 12 Bit resolution, CAN interface ISO11898-2 electrical isolated
CAN-CBM-AI410
C.2835.02CAN-CBM-AI410 CANbloc-Mini-Module 4 analog inputs, 0..10 V, 10 Bit resolution, CAN Interface ISO-11898-2, electrically isolated, CANopen profile CiA401
CAN-CBM-AI410-T
C.2835.044x10 Bit AnalogIn, CANbloc-Mini-Modul (CANopen), 4 analog inputs, 0..10 V, 10 bit resolution, CAN high speed interface, ISO-11898-2, electrically isolated, Extended temperature range: -20C..+85C
CAN-CBM-Bridge/2
C.2853.02Compact module-DIN rail mountable, 2 CAN interfaces, physical layer according to ISO 11898, electrically isolated, up to 1 MBit/s, firmware with Bridge functionality, baudrate adjustable via software for each CAN Interface, additional RS-232 is used for configuration
CAN-CBM-Clock-Batterie
C.2836.03CAN-CBM-Clock Clock-Distribution DCF/GPS WICHTIG: Vor Auslieferung Prüfung der Lithiumbatterie bzgl. Lagerdauer!!! SVHC information acc. to article 33 of regulation (EC) 1907/2006 (REACH): This products is equipped with a lithium battery that contains the SVHC substance 1,2-dimethoxyethane, ethylene glycol dimethyl ether (EGDME) (CAS-no. 110-71-4) in a concentration of more than 0.1% w/w (related to the mass of the battery).
CAN-CBM-COM1 CANlayer2-to-RS232
C.2841.02CAN-CBM-COM1 CAN-to-RS232 CANbloc-Mini module for one serial interface with RS232 based on C505C CAN-Layer-2 with esd-700 protocol. CAN Interface ISO11898 with highspeed optocoupler.
CAN-CBM-DIO8
C.2830.02CANbloc-Mini-Module for CANopen, with 8 digital channels, 24V/1A, each individually programmable as Input or Output
CAN-CBM-DP
C.2844.03CANbloc-Mini DIN-rail module Profibus-DP-Slave / CAN-layer 2 Gateway, CAN-physical Layer according to ISO11898, electrically isolated data transfer rates up to 1 MBit/s, DP-Physical Layer: RS-485, electrically isolated; Manual and GSD file on CD-ROM
CAN-CBM-DP (2.0B)
C.2844.05CANbloc-Mini DIN-rail module Profibus-DP-Slave / CAN-layer 2 Gateway, for CAN 2.0B, 29 Bit support, CAN-physical Layer according to ISO11898, electrically isolated, data transfer rates up to 1 MBit/s, DP-Physical Layer: RS-485, electrically isolated; Manual and GSD file on CD-ROM; additionally the RS-232 can be used for service, development or configuration purposes
CAN-CBM-REL4
C.2833.01CANbloc-Mini-Module for CANopen 4 relay output, 2x changeover, 2x close; also available in extended temperature range -40-+85°C
CAN-CBX-AI420
C.3030.02CANopen module with 4 differential analog inputs via 24-bit Sigma-Delta ADC for voltage range ±10V. Inputs with up to 20-bit effective and 16-bit p-p resolution at sampling rates of up to 2kHz. Galvanic isolation of the analog inputs. CANopen according to CiA 301 and CiA 401 Device Profile for Generic I/O Modules. Connectors for wire end ferrules included in the scope of delivery.
CAN-CBX-AI814
C.3020.02CANopen module with 8 analog single-ended inputs for the ±10V voltage range. Inputs with 14-bit resolution, data rates up to 1kHz and galvanic isolation. CANopen according to CiA 301 and CiA 401 Device Profile for Generic I/O Modules. Connectors for wire end ferrules included in the scope of delivery.
CAN-CBX-AO412
C.3040.02CANopen module with 4 analog ±10V outputs and max. 10 mA output current. Outputs with 12-bit resolution plus sign and galvanically isolated. CANopen according to CiA 301 and CiA 401 Device Profile for Generic I/O Modules. Connectors for wire end ferrules included in the scope of delivery.
CAN-CBX-Bridge-FD
C.3090.02CAN DIN rail module with 2 CAN FD interfaces with up to 8 MBit/s and physical layer according to ISO-11898 with galvanic isolation on COMBICON connectors. Firmware with bridge function for setting baud rate and filters for each CAN interface via serial RS-232 configuration interface.
CAN-CBX-COM2 2xRS232
C.3055.02CANopen module for 2 serial RS232 interfaces. Configuration and protocol according CANopen DS301, CAN Interface according to ISO 11898, galvanic isolation via optocoupler, supports In-Rail-Bus
CAN-CBX-CPU5201 Linux
C.3071.02PowerPC MPC5121 with FPU, 400MHz 0,5 GB DRAM, 1 GB Flash, RTC 1x 10/100BASE-T Ethernet, 1x RS-232 1x USB-Host 2.0, Full-Speed 1x CAN, ISO 11898-2, optical isolated 1x CAN, ISO 11898-2 on In-Rail-Bus; Operating system: Linux
CAN-CBX-CPU5201 QNX
C.3071.04PowerPC MPC5121 with FPU, 400MHz, 0,5 GB DRAM, 1 GB Flash, RTC, 1x 10/100BASE-T Ethernet, 2x RS-232 serial port, 1x USB-Host 2.0, full speed, 1x CAN, ISO 11898-2, optical isolated, 1x CAN, ISO 11898-2 on In-Rail bus; Operating system: QNX 6.4
CAN-CBX-CPU5201/DP QNX
C.3071.06PowerPC MPC5121 with FPU, 400MHz, 0.5 GB DRAM, 1 GB Flash, RTC, 1x 10/100BASE-T Ethernet, 2x RS-232 1x USB host 2.0, full speed 1x CAN, ISO 11898-2, optical isolated, 1x CAN, ISO 11898-2 on in-rail bus for extension with CBX-IO modules 1x Profibus-DP slave, VPC3+ Profibus controller, optical isolated; Operating system: QNX 6.4;
CAN-CBX-DIO8
C.3010.02CANopen module with 8 digital channels with 24V/1A each, each channel can be configured independently as an input or output. CANopen according to CiA 301 and CiA 401 Device Profile for Generic I/O Modules. Connectors for wire end ferrules included in the scope of delivery.
CAN-CBX-Pt100
C.3032.02CANopen module with 4 independent channels with 24-bit Sigma-Delta ADC for high-precision RTD (e.g. Pt100 or Ni100) and resistance measurements. Measurements in two- or four-wire technology with selectable sampling rates of up to 1000 PLC. CANopen according to CiA 301 and CiA 404 Device Profile Measuring Devices. Connectors for wire end ferrules included in the scope of delivery.
CAN-CBX-REL4
C.3012.02CANopen module with 4 relay channels, designed as 2x make contact and 2x changeover contact for switching voltages up to max. 250VAC/125VDC and switching currents up to max. 8A. CANopen according to CiA 301 and CiA 401 Device Profile for Generic I/O Modules. Connectors for wire end ferrules included in the scope of delivery.
CAN-CBX-REL4/2
C.3012.04CANopen module with 4 relay channels, designed as 2x make contact and 2x changeover contact for switching voltages up to max. 250VAC/125VDC and switching currents up to max. 8A. CANopen according to CiA 301 and CiA 401 Device Profile for Generic I/O Modules. Connectors for wire end ferrules included in the scope of delivery.
CAN-CBX-TBus
C.3000.01In-Rail-Bus connector
CAN-CBX-TBus-Connector-Socket
C.3000.02to connect power supply (24V) and CAN at CBX-In-Rail-Bus. socket type
CAN-CBX-THERMO
C.3034.02CANopen module with 4 independent, galvanically isolated channels with 24-bit Sigma-Delta ADC for high-precision temperature and voltage measurements. Suitable for thermocouples of types J, K, B, E, N, R, S or T as well as integrated cold junction compensation. CANopen according to CiA 301 and CiA 404 Device Profile Measuring Devices. Connector plug for wire end ferrules included in the scope of delivery.
CAN-DP
C.2905.02Gateway CAN/Profibus-DP-Slave, CPU PPC405, 133MHz, DRAM, Flash, 1x CAN controller SJA1000, CAN physial layer according ISO-11898 with optical isolation up to 1 MBit/s, CAN 2.0A/B, DP physical layer: RS-485 with optical isolation up to 12 MBit/s; manual and GSD file on CD-ROM; hat rail mounted device
CAN-DP/2
C.2907.02Gateway CAN to Profibus-DP slave, Operating voltage: typ. 24VDC, ARM Cortex M3 microcontroller with integrated CAN-Controller, ISO 11898-1, CAN physical layer ISO 11898-2, up to 1 MBit/s, galv. isolation, VPC3 Profibus-DP slave controller, DP physical layer: RS-485, up to 12 MBit/s, galv. isolation; Firmware with gateway function, Manual and GSD file on CD-ROM
CAN-EtherCAT
C.2922.02EtherCAT to CAN gateway for DIN rail mounting. Can be integrated as EtherCAT slave according to ETG modular device profile No. 5000. Galvanically isolated CAN interface according to ISO-11898 with up to 1 MBit/s. The CAN EtherCAT is configured via the EtherCAT master and standard EtherCAT configuration tools. Also usable as Ethernet switch port device for integration of Ethernet into EtherCAT.
CAN-PN
C.2920.02CAN to PROFINET-IO-Device Gateway with ERTEC200 and SJA1000. CAN interface according to ISO-11898 with electrical isolation via 5-pin connector. PROFINET-Physical Layer 100BASE-TX according to IEEE802.3 with integrated switch on 2x RJ45 jacks. The module can be mounted on the DIN rail and has an InRailBus option. Manual and GSD files are supplied on CD.
CAN-PN/2
C.2924.02High-performance CAN to PROFINET-IO device gateway with wide range of configuration options. CAN interface according to ISO-11898 with galvanic isolation and PROFINET physical layer 100BASE-TX according to IEEE802.3 with integrated switch for DIN rail mounting. Comprehensive debugging options with CAN diagnostic software CANreal via USB interface.
CAN-PN/2-FD
C.2924.62High-performance CAN FD to PROFINET-IO device gateway with a wide range of configuration options. CAN FD interface according to ISO-11898 with galvanic isolation and PROFINET physical layer 100BASE-TX according to IEEE802.3 with integrated switch for DIN rail mounting. Extensive debugging possibilities with CAN diagnostic software CANreal via USB interface.
CAN-Repeater-I
C.1330.02CAN repeater with 2 CAN channels, DSUB-9 connector and DIN-rail mount, physical layer according to ISO 11898, termination resistances 120 ohms, supply voltage 8-24 VDC
CAN-Repeater-Y
C.1330.03CAN-Repeater with 3 CAN interfaces, DSUB-9 and DIN-rail mount, physical layer according to ISO11898, termination resistors 120 Ohm, power supply 8 - 24 VDC
CAN-Repeater-Y-Opto
C.1330.07CAN-Repeater with 3 CAN interfaces, DSUB-9 and DIN-rail mount, physical layer according to ISO11898, termination resistors 120 Ohm, power supply 8 - 24 VDC, galvanic isolation of one CAN interface
CAN-USB/2-DINrail
C.2066.03Intelligent CAN interface for the USB interface in a compact and robust aluminum housing for DIN rail mounting. Supports USB 2.0 High Speed with up to 480 MBit/s and CAN High-Speed with Physical Layer according to ISO 11898-2 with optical isolation and a CAN data rate of up to 1 MBit/s. The module is powered via USB. Drivers and tools for Windows are included. Support for Linux is provided via SocketCAN.
CAN-USB/3-FD-DINrail
C.2076.63Intelligent CAN FD interface for the USB interface in a compact and robust aluminum housing for DIN rail mounting. Supports USB 2.0 High Speed with up to 480 MBit/s and CAN High-Speed with Physical Layer according to ISO 11898-2 with optical isolation and a CAN data rate of up to 8 MBit/s. The module is powered via USB. Drivers and tools for Windows are included. Support for Linux is provided via SocketCAN.
CANopen-DP
C.2908.02Gateway CANopen/Profibus-DP slave, CPU PPC405, 133 MHz, DRAM, Flash, 1x CAN controller SJA1000, CAN physial layer ISO-11898 with optical isolation up to 1 MBit/s, CAN 2.0A/B, DP physical layer: RS-485 with optical isolation up to 12 MBit/s; gateway firmware for CANopen (NMT, PDO, SDO, Heartbeat etc.) and Profibus-DP-V1, manual and GSD file on CD-ROM
CANopen-DP/2
C.2909.02Gateway CANopen to Profibus-DP slave, Operating voltage: typ. 24VDC, ARM Cortex M3 microcontroller, with integrated CAN-Controller, ISO 11898-1, CAN physical layer ISO 11898-2, up to 1 MBit/s, galv. isolation, VPC3 Profibus-DP slave controller, DP physical layer: RS-485, up to 12 MBit/s, galv. isolation; Firmware with gateway function Manual and GSD file on CD-ROM
CANopen-PN
C.2921.02PROFINET-IO-Device to CANopen Manager Gateway based on ERTEC 400. CAN-Physical-Layer according to ISO-11898-2 and PROFINET-Physical -Layer 100BASE-TX according to IEEE802.3 with galvanic isolation on both sides. Compact housing for DIN rail mounting with easily accessible connectors. System integration using the esd GSDML composer for individual generation of the matching configuration. Extensive debugging with CAN diagnostic software (CANreal, CANplot and COBview) via USB interface.
CANopen-PN/2
C.2931.02High-performance PROFINET-IO-Device to CANopen Manager Gateway. CAN-Physical-Layer according to ISO-11898-2 and PROFINET-Physical -Layer 100BASE-TX according to IEEE802.3 with galvanic isolation on both sides. Compact housing for DIN rail mounting with easily accessible connectors. System integration using the esd GSDML composer for individual generation of the matching configuration. Extensive debugging with CAN diagnostic software (CANreal, CANplot and COBview) via USB interface.
DN-CBM-DP
C.2846.02CANbloc-Mini DIN-rail module Profibus-DP-Slave / DeviceNet Gateway, DeviceNet electrically isolated, DP-Physical Layer: RS-485, electrically isolated; Manual and GSD file on CD-ROM; additionally the RS-232 can be used for service, development or configuration purposes
DN-DP
C.2930.02Gateway Devicenet/Profibus-DP-Slave, CPU PPC405, 133 MHz, DRAM, Flash, DeviceNet electrically isolated, DP-Physical Layer: RS-485, electrically isolated; Devicenet Scanner or Slave, Profibus DP Slave, Manual and GSD file on CD-ROM, DIN-rail mountable
ECX-DIO8
E.3010.02EtherCAT IO module with 8 digital channels, 24V/500mA, each IO programmable as input or output seperately
ECX-EC
E.3022.02Module for cummunication between 2 independent EtherCAT networks with slave in- and out-port per network, as well as an Ethernet interface for Ethernet over EtherCAT (EoE). The housing can be mounted on a DIN rail. Manual, ESI file and EtherCAT Workbench (test version) are included.
ECX-ETH-Selector
E.3025.01EtherCAT / Ethernet Master Selector for 1000BASE-TX (10/100/1000 Mbit/s) connections, IEEE 802.3, 24VDC, rail mounting
ECX-Master-Selector
E.3021.01Dual EtherCAT Redundant Master Selector, IEEE 802.3, 24VDC, rail mounting
ECX-PoE-PE
E.3020.02Power-Extractor for InRailBus Output Voltage: 24 V-DC Output Power: 20 W Can be used with ECX-und CBX-modules
EPPC-T10
I.2007.02Embedded PowerPC mit Freescale QorIQ T1014, 1x 1,2 GHz, 64 Bit, FPU 3x GB-Ethernet 1x USB 2.0 1x RS232 1x SATA, 1x MiniPCIe 1x SD-Card slot
EtherCAN/2
C.2051.02Ethernet-CAN-Gateway, DIN rail-mountable, 10/100 BaseT Ethernet, CAN interface according ISO 11898-1 with highspeed transceiver (ISO 11898-2) for bit rates up to 1 Mbit/s; optical isolated, integrated WEB-interface, nom. operating voltage 24 VDC; Drivers, tools and documentation for Windows & Linux on CD-ROM
J1939-Starter-Kit USB/2 for Windows
C.1130.09CAN-USB/2 interface module, J1939 Stack for esd CAN-Hardware, Windows object code, includes J1939 Simulation Tool; includes I/O Module with J1939 ECU functionality; complete wiring for 2 CAN nodes; Drivers, tools and documentation for Windows & Linux on CD-ROM
Switch16/Com3
A.1109.0116 Ports RJ45 10/100/1000 Mbit, Web-based configuration, DHCP Client, DHCP Server, VLANs, COM-Server 3 x RS232/422/485 per Software selectable; Driver for Windows 7/10 (32/64bit), 24VDC Power Supply; DIN rail mounting, IP20