Overview of all products
Here you can see all our order items. Use the extensive filter options to find the suitable product for you.
With the help of the button "Add to watchlist" you can save articles on your watchlist.
Afterwards, you can request your saved watch list as a quotation via a contact form.
Please feel free to contact us
If you have any questions or would like more information, please do not hesitate to contact our sales team.
Contact us
Telephone: +49 (0) 511 37298-0
E-Mail: sales@esd.eu
Selected filters
Categories
- Accessories (4)
- CAN Bus (37)
- CAN Interface (3)
- CPU Board/Module (4)
- EtherCAT (7)
- Gateway/Bridge (21)
- IO-Modules (17)
- Networking (5)
- Software (1)
Number CAN-Channels
Protocols
- CAN FD-Layer 2 (2)
- CAN-Layer 2 (37)
- CANopen (26)
- DeviceNet (2)
- EtherCAT (10)
- Ethernet (6)
- Ethernet/IP (2)
- J1939 (4)
- Profibus (8)
- PROFINET (7)
Supported operating systems
Interfaces
- CAN (40)
- CAN FD (2)
- CANopen Device (16)
- CANopen Manager (4)
- DeviceNet (2)
- EtherCAT Slave (3)
- Ethernet (10)
- PCIe (1)
- Profibus (8)
- PROFINET (5)
- Serial Interface (8)
- USB (7)
Features
- CiA 301 compliant (17)
- CiA 401 profile (15)
- CiA 404 profile (1)
- EtherCAT Master capable (4)
- EtherCAT Slave capable (3)
- galvanically isolated (42)
- HW-Timestamp capable (2)
- Software Bundle (1)
- Starter Kit (1)
I/O Types
CANopen-DP
C.2908.02Gateway CANopen/Profibus-DP slave, CPU PPC405, 133 MHz, DRAM, Flash, 1x CAN controller SJA1000, CAN physial layer ISO-11898 with optical isolation up to 1 MBit/s, CAN 2.0A/B, DP physical layer: RS-485 with optical isolation up to 12 MBit/s; gateway firmware for CANopen (NMT, PDO, SDO, Heartbeat etc.) and Profibus-DP-V1, manual and GSD file on CD-ROM
CANopen-PN
C.2921.02PROFINET-IO-Device to CANopen Manager Gateway based on ERTEC 400. CAN-Physical-Layer according to ISO-11898-2 and PROFINET-Physical -Layer 100BASE-TX according to IEEE802.3 with galvanic isolation on both sides. Compact housing for DIN rail mounting with easily accessible connectors. System integration using the esd GSDML composer for individual generation of the matching configuration. Extensive debugging with CAN diagnostic software (CANreal, CANplot and COBview) via USB interface.
DN-CBM-DP
C.2846.02CANbloc-Mini DIN-rail module Profibus-DP-Slave / DeviceNet Gateway, DeviceNet electrically isolated, DP-Physical Layer: RS-485, electrically isolated; Manual and GSD file on CD-ROM; additionally the RS-232 can be used for service, development or configuration purposes
DN-DP
C.2930.02Gateway Devicenet/Profibus-DP-Slave, CPU PPC405, 133 MHz, DRAM, Flash, DeviceNet electrically isolated, DP-Physical Layer: RS-485, electrically isolated; Devicenet Scanner or Slave, Profibus DP Slave, Manual and GSD file on CD-ROM, DIN-rail mountable
AMC-ADIO-Adapter
U.1001.10DIN-EN rail mounting module connecting 10-pin har-link socket connector to 14-pin COMBICON style connector FK-MCP 1,5/14-STF-3,81.
AMC-ADIO24-HD50-Adapter
U.1001.09Adapter from SCSI connector 50-pin connector via ribbon cable (0,5m) to transfer/interface modules (50-pin, screw connection, mounting on standard DIN rail)
CAN-CBM-AI4
C.2831.02CANopen module, 4 analog inputs, 0...10V / 0...20mA, 12 Bit resolution, CAN interface ISO11898-2 electrical isolated
CAN-CBM-AI410
C.2835.02CAN-CBM-AI410 CANbloc-Mini-Module 4 analog inputs, 0..10 V, 10 Bit resolution, CAN Interface ISO-11898-2, electrically isolated, CANopen profile CiA401
CAN-CBM-AI410-T
C.2835.044x10 Bit AnalogIn, CANbloc-Mini-Modul (CANopen), 4 analog inputs, 0..10 V, 10 bit resolution, CAN high speed interface, ISO-11898-2, electrically isolated, Extended temperature range: -20C..+85C
CAN-CBM-Clock-Batterie
C.2836.03CAN-CBM-Clock Clock-Distribution DCF/GPS WICHTIG: Vor Auslieferung Prüfung der Lithiumbatterie bzgl. Lagerdauer!!! SVHC information acc. to article 33 of regulation (EC) 1907/2006 (REACH): This products is equipped with a lithium battery that contains the SVHC substance 1,2-dimethoxyethane, ethylene glycol dimethyl ether (EGDME) (CAS-no. 110-71-4) in a concentration of more than 0.1% w/w (related to the mass of the battery).
CAN-CBM-COM1 CANlayer2-to-RS232
C.2841.02CAN-CBM-COM1 CAN-to-RS232 CANbloc-Mini module for one serial interface with RS232 based on C505C CAN-Layer-2 with esd-700 protocol. CAN Interface ISO11898 with highspeed optocoupler.
CAN-CBM-DIO8
C.2830.02CANbloc-Mini-Module for CANopen, with 8 digital channels, 24V/1A, each individually programmable as Input or Output
CAN-CBM-REL4
C.2833.01CANbloc-Mini-Module for CANopen 4 relay output, 2x changeover, 2x close; also available in extended temperature range -40-+85°C
CAN-CBX-AI420
C.3030.02CANopen module with 4 differential analog inputs via 24-bit Sigma-Delta ADC for voltage range ±10V. Inputs with up to 20-bit effective and 16-bit p-p resolution at sampling rates of up to 2kHz. Galvanic isolation of the analog inputs. CANopen according to CiA 301 and CiA 401 Device Profile for Generic I/O Modules. Connectors for wire end ferrules included in the scope of delivery.
CAN-CBX-AI814
C.3020.02CANopen module with 8 analog single-ended inputs for the ±10V voltage range. Inputs with 14-bit resolution, data rates up to 1kHz and galvanic isolation. CANopen according to CiA 301 and CiA 401 Device Profile for Generic I/O Modules. Connectors for wire end ferrules included in the scope of delivery.
CAN-CBX-AO412
C.3040.02CANopen module with 4 analog ±10V outputs and max. 10 mA output current. Outputs with 12-bit resolution plus sign and galvanically isolated. CANopen according to CiA 301 and CiA 401 Device Profile for Generic I/O Modules. Connectors for wire end ferrules included in the scope of delivery.
CAN-CBX-COM2 2xRS232
C.3055.02CANopen module for 2 serial RS232 interfaces. Configuration and protocol according CANopen DS301, CAN Interface according to ISO 11898, galvanic isolation via optocoupler, supports In-Rail-Bus
CAN-CBX-DIO8
C.3010.02CANopen module with 8 digital channels with 24V/1A each, each channel can be configured independently as an input or output. CANopen according to CiA 301 and CiA 401 Device Profile for Generic I/O Modules. Connectors for wire end ferrules included in the scope of delivery.
CAN-CBX-Pt100
C.3032.02CANopen module with 4 independent channels with 24-bit Sigma-Delta ADC for high-precision RTD (e.g. Pt100 or Ni100) and resistance measurements. Measurements in two- or four-wire technology with selectable sampling rates of up to 1000 PLC. CANopen according to CiA 301 and CiA 404 Device Profile Measuring Devices. Connectors for wire end ferrules included in the scope of delivery.
CAN-CBX-THERMO
C.3034.02CANopen module with 4 independent, galvanically isolated channels with 24-bit Sigma-Delta ADC for high-precision temperature and voltage measurements. Suitable for thermocouples of types J, K, B, E, N, R, S or T as well as integrated cold junction compensation. CANopen according to CiA 301 and CiA 404 Device Profile Measuring Devices. Connector plug for wire end ferrules included in the scope of delivery.
CAN-Repeater-I
C.1330.02CAN repeater with 2 CAN channels, DSUB-9 connector and DIN-rail mount, physical layer according to ISO 11898, termination resistances 120 ohms, supply voltage 8-24 VDC
CAN-Repeater-Y
C.1330.03CAN-Repeater with 3 CAN interfaces, DSUB-9 and DIN-rail mount, physical layer according to ISO11898, termination resistors 120 Ohm, power supply 8 - 24 VDC
CAN-CBX-REL4
C.3012.02CANopen module with 4 relay channels, designed as 2x make contact and 2x changeover contact for switching voltages up to max. 250VAC/125VDC and switching currents up to max. 8A. CANopen according to CiA 301 and CiA 401 Device Profile for Generic I/O Modules. Connectors for wire end ferrules included in the scope of delivery.