Overview of all products
Here you can see all our order items. Use the extensive filter options to find the suitable product for you.
With the help of the button "Add to watchlist" you can save articles on your watchlist.
Afterwards, you can request your saved watch list as a quotation via a contact form.
Please feel free to contact us
If you have any questions or would like more information, please do not hesitate to contact our sales team.
Contact us
Telephone: +49 (0) 511 37298-0
E-Mail: sales@esd.eu
Selected filters
Categories
- Accessories (30)
- CAN Bus (81)
- CAN Interface (24)
- CPU Board/Module (1)
- EtherCAT (1)
- Gateway/Bridge (16)
- IO-Modules (16)
- Slot card system (5)
- Software (1)
Formfactors
Protocols
- ARINC825 (6)
- CAN FD-Layer 2 (5)
- CAN-Layer 2 (53)
- CANopen (43)
- EtherCAT (2)
- Ethernet (2)
- J1939 (24)
- OPC UA (1)
- Profibus (6)
- PROFINET (5)
Supported operating systems
- Linux (22)
- On Time RTOS-32 (9)
- QNX4 (3)
- QNX6/7 (15)
- RTOS-UH (2)
- RTX (9)
- RTX64 (11)
- SGI-IRIX6.5 (1)
- Solaris (1)
- TenAsys INtime 6/7 (6)
- VxWorks (14)
- Windows 10/11 (2)
- Windows 7/8/10/11 (20)
- Windows CE.NET (3)
Interfaces
- CAN (57)
- CAN FD (6)
- CANopen Device (16)
- CANopen Manager (4)
- EtherCAT Slave (1)
- Ethernet (3)
- ISA (3)
- PCI (10)
- PCIe (4)
- Profibus (6)
- PROFINET (5)
- Serial Interface (2)
- USB (6)
Features
- Bus-Mastering (DMA-Support) (6)
- CiA 301 compliant (14)
- CiA 401 profile (15)
- CiA 404 profile (1)
- esd Advanced CAN Controller (esdACC) (6)
- EtherCAT Master capable (1)
- EtherCAT Slave capable (1)
- Expansion board (3)
- galvanically isolated (55)
- HW-Timestamp capable (10)
- Low profile slot version (5)
- MSI-IRQ capable (6)
- Software Bundle (1)
- Starter Kit (1)
I/O Types
CAN-CBX-AI814
C.3020.02CANopen module with 8 analog single-ended inputs for the ±10V voltage range. Inputs with 14-bit resolution, data rates up to 1kHz and galvanic isolation. CANopen according to CiA 301 and CiA 401 Device Profile for Generic I/O Modules. Connectors for wire end ferrules included in the scope of delivery.
CAN-CBX-AO412
C.3040.02CANopen module with 4 analog ±10V outputs and max. 10 mA output current. Outputs with 12-bit resolution plus sign and galvanically isolated. CANopen according to CiA 301 and CiA 401 Device Profile for Generic I/O Modules. Connectors for wire end ferrules included in the scope of delivery.
CAN-CBX-COM2 2xRS232
C.3055.02CANopen module for 2 serial RS232 interfaces. Configuration and protocol according CANopen DS301, CAN Interface according to ISO 11898, galvanic isolation via optocoupler, supports In-Rail-Bus
CAN-CBX-DIO8
C.3010.02CANopen module with 8 digital channels with 24V/1A each, each channel can be configured independently as an input or output. CANopen according to CiA 301 and CiA 401 Device Profile for Generic I/O Modules. Connectors for wire end ferrules included in the scope of delivery.
CAN-CBX-Pt100
C.3032.02CANopen module with 4 independent channels with 24-bit Sigma-Delta ADC for high-precision RTD (e.g. Pt100 or Ni100) and resistance measurements. Measurements in two- or four-wire technology with selectable sampling rates of up to 1000 PLC. CANopen according to CiA 301 and CiA 404 Device Profile Measuring Devices. Connectors for wire end ferrules included in the scope of delivery.
CAN-CBX-THERMO
C.3034.02CANopen module with 4 independent, galvanically isolated channels with 24-bit Sigma-Delta ADC for high-precision temperature and voltage measurements. Suitable for thermocouples of types J, K, B, E, N, R, S or T as well as integrated cold junction compensation. CANopen according to CiA 301 and CiA 404 Device Profile Measuring Devices. Connector plug for wire end ferrules included in the scope of delivery.
CAN-CPCI/331-1 1xCAN-2.0A/B
C.2027.02active CompactPCI-CAN interface board, 3U/4HP CompactPCI board, 1x CAN interface preset to CAN 2.0 A (switchable to 2.0 B), physical layer according to ISO 11898, electrically isolated, drivers, tools and documentation for Windows & Linux on CD-ROM
CAN-PCI104/200-DSUB/10pol. CAN
C.2046.70CAN adapter cable with 10-pin socket connector to DSUB9 (pins) as 30 cm ribbon cable
CAN-Repeater-I
C.1330.02CAN repeater with 2 CAN channels, DSUB-9 connector and DIN-rail mount, physical layer according to ISO 11898, termination resistances 120 ohms, supply voltage 8-24 VDC
CAN-Repeater-Y
C.1330.03CAN-Repeater with 3 CAN interfaces, DSUB-9 and DIN-rail mount, physical layer according to ISO11898, termination resistors 120 Ohm, power supply 8 - 24 VDC
PMC-CAN/331-1 1xCAN
C.2025.02Intelligent PMC-CAN-Interface, MC 683331 with PLX 9052 bridge, 1 CAN 2.0A/B-interface (SJA1000), ISO11898, electrically isolated; data transfer rates up to 1 MBit/s, firmware integrated, Drivers, tools and documentation for Windows & Linux on CD-ROM
PMC-CAN/331/3.3-1 1xCAN
C.2039.01Intelligent PMC-CAN-Interface, MC 683331 with PLX 9030 bridge, 1 CAN 2.0A/B-interface (SJA1000), 3.3V on PCI, ISO11898, electrically isolated, data transfer rates up to 1 MBit/s; firmware integrated, Drivers, tools and documentation for Windows & Linux on CD-ROM