Expansion of the CAN network
- Connects 2 or 3 CAN networks
- Improves the load capacity of the CAN bus with participants
-
Available with or without electrical isolation
Industry-suitable Design
-
CAN interface according to ISO 11898-2, data rate up to 1 Mbit/s
-
Operating voltage range: 8 V ... 30 V
-
Compact housing for DIN-EN carrier rail mounting (TS 35)
Arbitration
- fast logic ensures complete transparency and flawless arbitration of CAN objects in all connected networks
I- or Y- Repeater
The I-Repeater can be used to improve the participant capacity of the CAN bus or to insert an electrical isolation (only possible in design ‘-Opto’). The Y-Repeater makes a branch from one to two CAN lines.
Physical Layer
All CAN interfaces of the repeaters comply with ISO 11898. Each Repeater is available without electrical isolation or with an electrically insulated interface. The maximum transfer rate is 1 Mbit/s. The bit timing has to be the same at all connections. Each CAN interface has a terminating impedance of 120 ohm in the repeater.
With the help of the button "Add to watchlist" you can save articles on your watchlist.
Afterwards, you can request your saved watch list as a quotation via a contact form.
Hardware
CAN-Repeater with 3 CAN interfaces, DSUB-9 and DIN-rail mount, physical layer according to ISO11898, termination resistors 120 Ohm, power supply 8 - 24 VDC, galvanic isolation of one CAN interface
- galvanically isolated
- CAN
- CAN-Layer 2